Search found 13 matches

by vcatuor
Tue Jul 02, 2024 7:50 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: SNMP Reply format - Conversion
Replies: 7
Views: 12279

Re: SNMP Reply format - Conversion

It finally worked, I had to change the locales (to use a . instead of a ,) on the account that was running Advanced Host Monitor Windows Service on the server, and that solved it

Thanks for the support
by vcatuor
Fri Jun 28, 2024 9:59 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: SNMP Reply format - Conversion
Replies: 7
Views: 12279

Re: SNMP Reply format - Conversion

Well yes you're right, sorry for the confusion, as I launched Real Time Charts directly from HostMonitor. It's version 14.54
by vcatuor
Fri Jun 28, 2024 12:08 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: SNMP Reply format - Conversion
Replies: 7
Views: 12279

Re: SNMP Reply format - Conversion

Thanks for the reply, In fact the return Number is OK (with a dot), and shown correctly by the 'real time chart', and I can do alerts based on the reply with decimal, but the 'history charts' only show data when I use results without decimals, as soon as I have decimals as replies, it shows blank :o
by vcatuor
Thu Jun 27, 2024 9:41 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: SNMP Reply format - Conversion
Replies: 7
Views: 12279

SNMP Reply format - Conversion

Hi, We just installed a temperature monitoring unit (HWg STE2 r2) The thing is we have 2 OIDs for C temperature, the first is the correct temperature but returned in 'String' and the second is without separator, and returns an INT, as shown below 1.3.6.1.4.1.21796.4.9.3.1.4.1 23.7 1. Sensor String V...
by vcatuor
Tue Jun 18, 2024 6:11 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: MIB Browser (local) not seeing SNMP Profile
Replies: 3
Views: 8423

Re: MIB Browser (local) not seeing SNMP Profile

It's version 2.12, launched through RCC (on my local machine), AHM is installed on a separate machine.

In fact, I probably 'mis-installed' it I just reinstalled the RCC and put back the tools separately, which now seems to work much better, sorry for the inconvenience
by vcatuor
Tue Jun 18, 2024 1:52 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: MIB Browser (local) not seeing SNMP Profile
Replies: 3
Views: 8423

MIB Browser (local) not seeing SNMP Profile

Hi,
I added, through RCC, a custom SNMP profile, all good for my SNMP tests, but when I launch the MIB browser from the Tools menu, it doesn't see it, and I can't add one from there as a yellow sign indicates I should use RCC to create it (as I did) :-?
by vcatuor
Tue Jun 18, 2024 1:46 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: SMS Alerts
Replies: 5
Views: 9635

Re: SMS Alerts

Thanks for the reply, I can't find that model around here, any idea if Huawei E3372-325 would work too ?
by vcatuor
Mon Jun 17, 2024 6:47 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: SMS Alerts
Replies: 5
Views: 9635

Re: SMS Alerts

Hi, We do have Huawei normally, but the E220 is no more available and I'm struggling to find one in the list in AHM that I can (still ) buy over here :-?
by vcatuor
Mon Jun 17, 2024 2:57 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: SMS Alerts
Replies: 5
Views: 9635

SMS Alerts

Hi,

Does anyone have a recent good experience with implementing an SMS alerting ? There is a list of modems in AHM, but I'm gathering some feedback of a well working generally available modem to buy in order to implement this. Any feedback welcome :)
by vcatuor
Tue May 07, 2024 1:55 am
Forum: Bug reports
Topic: Printer Tests in 14.50 questioning
Replies: 1
Views: 8121

Printer Tests in 14.50 questioning

I've been testing the new printer tests , quite interesting, seems ok on most of our printers, one however gives tranges results, the Lexmark MS431dn (maybe because Lexmark changed (inverted) Imaging and toner OIDs for this model) Here's a screenshot to illustrate it : https://wp.tuor.net/wp-content...
by vcatuor
Wed Jan 31, 2024 9:36 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: Bulk Change of SNMP community string
Replies: 8
Views: 14574

Fair solution, thanks :-)
by vcatuor
Wed Jan 31, 2024 7:26 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: Bulk Change of SNMP community string
Replies: 8
Views: 14574

Bulk Change of SNMP community string

Hi,

I just noticed that I created over 100 SNMP test using the built-in public community provile instead of public v2, is there a way to bulk change this ? The Edit function selecting several tests doesn't permit that

Thanks in advance
by vcatuor
Fri Jan 26, 2024 1:53 am
Forum: Configuration, Maintenance, Troubleshooting
Topic: Master-Slave dependency list
Replies: 1
Views: 7541

Master-Slave dependency list

Hi, I've now been using AHM for a month or so and as things evolved a bit (used it 10 years ago in another company), getting used to it again (a huge time saver, love it), I do see, in the web console network map a n interesting view of relationships. However I can't find out why some nodes are link...