It finally worked, I had to change the locales (to use a . instead of a ,) on the account that was running Advanced Host Monitor Windows Service on the server, and that solved it
Thanks for the support
Search found 13 matches
- Tue Jul 02, 2024 7:50 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: SNMP Reply format - Conversion
- Replies: 7
- Views: 12279
- Fri Jun 28, 2024 9:59 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: SNMP Reply format - Conversion
- Replies: 7
- Views: 12279
Re: SNMP Reply format - Conversion
Well yes you're right, sorry for the confusion, as I launched Real Time Charts directly from HostMonitor. It's version 14.54
- Fri Jun 28, 2024 12:08 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: SNMP Reply format - Conversion
- Replies: 7
- Views: 12279
Re: SNMP Reply format - Conversion
Thanks for the reply, In fact the return Number is OK (with a dot), and shown correctly by the 'real time chart', and I can do alerts based on the reply with decimal, but the 'history charts' only show data when I use results without decimals, as soon as I have decimals as replies, it shows blank :o
- Thu Jun 27, 2024 9:41 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: SNMP Reply format - Conversion
- Replies: 7
- Views: 12279
SNMP Reply format - Conversion
Hi, We just installed a temperature monitoring unit (HWg STE2 r2) The thing is we have 2 OIDs for C temperature, the first is the correct temperature but returned in 'String' and the second is without separator, and returns an INT, as shown below 1.3.6.1.4.1.21796.4.9.3.1.4.1 23.7 1. Sensor String V...
- Tue Jun 18, 2024 6:11 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: MIB Browser (local) not seeing SNMP Profile
- Replies: 3
- Views: 8423
Re: MIB Browser (local) not seeing SNMP Profile
It's version 2.12, launched through RCC (on my local machine), AHM is installed on a separate machine.
In fact, I probably 'mis-installed' it I just reinstalled the RCC and put back the tools separately, which now seems to work much better, sorry for the inconvenience
In fact, I probably 'mis-installed' it I just reinstalled the RCC and put back the tools separately, which now seems to work much better, sorry for the inconvenience
- Tue Jun 18, 2024 1:52 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: MIB Browser (local) not seeing SNMP Profile
- Replies: 3
- Views: 8423
MIB Browser (local) not seeing SNMP Profile
Hi,
I added, through RCC, a custom SNMP profile, all good for my SNMP tests, but when I launch the MIB browser from the Tools menu, it doesn't see it, and I can't add one from there as a yellow sign indicates I should use RCC to create it (as I did)
I added, through RCC, a custom SNMP profile, all good for my SNMP tests, but when I launch the MIB browser from the Tools menu, it doesn't see it, and I can't add one from there as a yellow sign indicates I should use RCC to create it (as I did)

- Tue Jun 18, 2024 1:46 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: SMS Alerts
- Replies: 5
- Views: 9635
Re: SMS Alerts
Thanks for the reply, I can't find that model around here, any idea if Huawei E3372-325 would work too ?
- Mon Jun 17, 2024 6:47 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: SMS Alerts
- Replies: 5
- Views: 9635
Re: SMS Alerts
Hi, We do have Huawei normally, but the E220 is no more available and I'm struggling to find one in the list in AHM that I can (still ) buy over here 

- Mon Jun 17, 2024 2:57 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: SMS Alerts
- Replies: 5
- Views: 9635
SMS Alerts
Hi,
Does anyone have a recent good experience with implementing an SMS alerting ? There is a list of modems in AHM, but I'm gathering some feedback of a well working generally available modem to buy in order to implement this. Any feedback welcome
Does anyone have a recent good experience with implementing an SMS alerting ? There is a list of modems in AHM, but I'm gathering some feedback of a well working generally available modem to buy in order to implement this. Any feedback welcome

- Tue May 07, 2024 1:55 am
- Forum: Bug reports
- Topic: Printer Tests in 14.50 questioning
- Replies: 1
- Views: 8121
Printer Tests in 14.50 questioning
I've been testing the new printer tests , quite interesting, seems ok on most of our printers, one however gives tranges results, the Lexmark MS431dn (maybe because Lexmark changed (inverted) Imaging and toner OIDs for this model) Here's a screenshot to illustrate it : https://wp.tuor.net/wp-content...
- Wed Jan 31, 2024 9:36 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Bulk Change of SNMP community string
- Replies: 8
- Views: 14574
- Wed Jan 31, 2024 7:26 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Bulk Change of SNMP community string
- Replies: 8
- Views: 14574
Bulk Change of SNMP community string
Hi,
I just noticed that I created over 100 SNMP test using the built-in public community provile instead of public v2, is there a way to bulk change this ? The Edit function selecting several tests doesn't permit that
Thanks in advance
I just noticed that I created over 100 SNMP test using the built-in public community provile instead of public v2, is there a way to bulk change this ? The Edit function selecting several tests doesn't permit that
Thanks in advance
- Fri Jan 26, 2024 1:53 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Master-Slave dependency list
- Replies: 1
- Views: 7541
Master-Slave dependency list
Hi, I've now been using AHM for a month or so and as things evolved a bit (used it 10 years ago in another company), getting used to it again (a huge time saver, love it), I do see, in the web console network map a n interesting view of relationships. However I can't find out why some nodes are link...