Posted: Mon Jul 03, 2017 1:06 am Post subject: ShellScript VBScript returns nothing |
|
|
Hi guys,
I have created a vbscript that reads the date of the last installed Windows update.
The code runs fine from the prompt or from a compiler.
However, when run from HostMonitor it comes up empty.
Start Command:
Code: | cmd /c cscript /B /E:VBScript %Script% |
VBCode
Code: | HKEY_LOCAL_MACHINE = &H80000002
strComputer = "<target host>"
strUser = "<domain>\<username>"
strPassword = "<password>"
Set objSWbemLocator = CreateObject("wbemScripting.SwbemLocator")
Set objSWbemServices = objSWbemLocator.ConnectServer(strComputer, "root\default", strUser, strPassword)
Set objReg = objSWbemServices.Get("StdRegProv")
strKeyPath = "SOFTWARE\Microsoft\Windows\CurrentVersion\WindowsUpdate\Auto Update\Results\Install"
strEntryName = "LastSuccessTime"
objReg.GetStringValue HKEY_LOCAL_MACHINE, strKeyPath, strEntryName, strDate
WScript.StdOut.Write "scriptRes:Ok:" & strDate
|
Any ideas?
HM version: 10.64 running on W2K8R2 |
|
Back to top |
|
|
KS-Soft
Joined: 03 Apr 2002 Posts: 12793 Location: USA
|
Posted: Mon Jul 03, 2017 4:45 am Post subject: |
|
|
Add some checks into script, e.g.
Code: |
HKEY_LOCAL_MACHINE = &H80000002
strComputer = "<target host>"
strUser = "<domain>\<username>"
strPassword = "<password>"
On Error Resume Next
Set objSWbemLocator = CreateObject("wbemScripting.SwbemLocator")
Set objSWbemServices = objSWbemLocator.ConnectServer(strComputer, "root\default", strUser, strPassword)
If Err <> 0 Then
WScript.StdOut.Write statusUnknown & "connect error: " & Err.Description
WScript.Quit
End If
Set objReg = objSWbemServices.Get("StdRegProv")
If Err <> 0 Then
WScript.StdOut.Write statusUnknown & "StdRegProv error: " & Err.Description
WScript.Quit
End If
strKeyPath = "SOFTWARE\Microsoft\Windows\CurrentVersion\WindowsUpdate\Auto Update\Results\Install"
strEntryName = "LastSuccessTime"
objReg.GetStringValue HKEY_LOCAL_MACHINE, strKeyPath, strEntryName, strDate
If Err <> 0 Then
WScript.StdOut.Write statusUnknown & "GetString error: " & Err.Description
WScript.Quit
End If
WScript.StdOut.Write "scriptRes:Ok:" & strDate |
Regards
Alex |
|
Back to top |
|
|
Kris
Joined: 12 May 2010 Posts: 375
|
Posted: Mon Jul 03, 2017 9:07 am Post subject: |
|
|
Added some missing variables and more debugging.
Still the script runs through, resulting in status OK and an empty value for 'strDate'.
And it still runs from the prompt or any compiler and returns a date and time, no problem there.
Code: | On Error Resume Next
strComputer = "<target host>"
strUser = "<domain>\<username>"
strPassword = "<password>"
HKEY_LOCAL_MACHINE = &H80000002
strKeyPath = "SOFTWARE\Microsoft\Windows\CurrentVersion\WindowsUpdate\Auto Update\Results\Install"
strEntryName = "LastSuccessTime"
statusOk = "scriptRes:Ok:"
statusBad = "scriptRes:Bad:"
statusUnknown = "scriptRes:Unknown:"
Set objSWbemLocator = CreateObject("wbemScripting.SwbemLocator")
If Err <> 0 Then
WScript.StdOut.Write statusUnknown & "Create Object Error: " & Err.Description
WScript.Quit
End If
Set objSWbemServices = objSWbemLocator.ConnectServer(strComputer, "root\default", strUser, strPassword)
If Err <> 0 Then
WScript.StdOut.Write statusUnknown & "connect error: " & Err.Description
WScript.Quit
End If
Set objReg = objSWbemServices.Get("StdRegProv")
If Err <> 0 Then
WScript.StdOut.Write statusUnknown & "StdRegProv error: " & Err.Description
WScript.Quit
End If
objReg.GetStringValue HKEY_LOCAL_MACHINE, strKeyPath, strEntryName, strDate
If Err <> 0 Then
WScript.StdOut.Write statusUnknown & "GetString error: " & Err.Description
WScript.Quit
End If
WScript.StdOut.Write "scriptRes:Ok:" & strDate
|
|
|
Back to top |
|
|
KS-Soft Europe
Joined: 16 May 2006 Posts: 2832
|
Posted: Mon Jul 03, 2017 1:44 pm Post subject: |
|
|
Looks like your value is accessible only for 64 bit applications.
32 and 64 bit applications may retrieve 2 different values from the same registry key/value path.
You may test your key/value path using "Registry" test method (choose "use Win32 reg" then "use Win64 reg").
Another option for checking 32/64bit values is running script from 32/64bit command prompt (to start 32bit command prompt start %windir%\SysWoW64\cmd.exe)
If that's the case, you may modify your script to check 64bit registry values:
You need to replace
Code: | Set objSWbemServices = objSWbemLocator.ConnectServer(strComputer, "root\default", strUser, strPassword) |
with:
Code: | Set arch = CreateObject("WbemScripting.SWbemNamedValueSet")
arch.Add "__ProviderArchitecture", 64
arch.Add "__RequiredArchitecture", True
Set objSWbemServices = objSWbemLocator.ConnectServer(strComputer, "root\default", strUser, strPassword,,,,arch) |
|
|
Back to top |
|
|
Kris
Joined: 12 May 2010 Posts: 375
|
Posted: Tue Jul 04, 2017 12:44 am Post subject: |
|
|
Works like a charm!
Thanks a lot! |
|
Back to top |
|
|
KS-Soft Europe
Joined: 16 May 2006 Posts: 2832
|
Posted: Tue Jul 04, 2017 6:55 am Post subject: |
|
|
You are welcome! |
|
Back to top |
|
|
|
|