Alex,
I am going to discuss this with my staff and get back to you in a couple of days.
Search found 95 matches
- Wed Mar 09, 2022 1:16 pm
- Forum: Other
- Topic: The Future Of HostMonitor
- Replies: 35
- Views: 131589
- Wed Mar 09, 2022 1:07 pm
- Forum: Other
- Topic: The Future Of HostMonitor
- Replies: 35
- Views: 131589
Alex Great to hear about your plans! My votes are for the following: Azure platform covered by Hostmonitor Sonicwall tests IPMI Tests RCC Android Improved Web Interface - I would really prefer a more functional web interface so that we would not need to use RCC. I might add a few more after some add...
- Sat Apr 03, 2021 7:49 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: AppendFile Syntax
- Replies: 1
- Views: 6481
AppendFile Syntax
Hello, What is the correct syntax (if possible) for append file where I want to append a log for the current week and also the previous week using macro variables. I have %WW%_%YY% and I want to add the previous week can I use %WW%[-1]_%YY% or something similar to that? this is in use but I want to ...
- Mon Mar 01, 2021 10:16 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: IPMI Test Failure Status
- Replies: 5
- Views: 11680
- Sat Feb 27, 2021 12:34 pm
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: IPMI Test Failure Status
- Replies: 5
- Views: 11680
- Sat Feb 27, 2021 11:45 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: IPMI Test Failure Status
- Replies: 5
- Views: 11680
IPMI Test Failure Status
Hello, We started using the new IPMI test. We did not receive an alert for a server that has a bad power supply. The power supply failed BEFORE we started using the new IPMI status, but the server still shows a status of "PS Failed" (Supermicro IPMI) . If this test looks at the log then I ...
- Tue Nov 03, 2020 9:51 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Start Second test automatically after other test Finishes
- Replies: 4
- Views: 10019
- Tue Nov 03, 2020 9:24 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Start Second test automatically after other test Finishes
- Replies: 4
- Views: 10019
Yes that is how I had set it up, with the dependent (second) test running every 23 hours. For some reason the second test is not starting directly after the master test completes, and that is what I want to happen. I have synchronize counters on for the second test. I think it was working at one poi...
- Mon Nov 02, 2020 9:58 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Start Second test automatically after other test Finishes
- Replies: 4
- Views: 10019
Start Second test automatically after other test Finishes
I have an external program test that can take a variable amount of time to complete, it returns 0 when successful, it will run on a schedule of 4 times per day. As soon as it completes, I want to execute a second test, a text log test, to read the results from a file created by the first test. I can...
- Wed Nov 28, 2018 6:48 am
- Forum: Wish list
- Topic: Additional Alert options
- Replies: 4
- Views: 36565
- Tue Jan 09, 2018 7:02 am
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Crash Issue in 11.00 - Related to ActiveRMA
- Replies: 9
- Views: 24340
- Mon Jan 08, 2018 9:11 pm
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Crash Issue in 11.00 - Related to ActiveRMA
- Replies: 9
- Views: 24340
- Mon Jan 08, 2018 9:07 pm
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Crash Issue in 11.00 - Related to ActiveRMA
- Replies: 9
- Views: 24340
I changed the port for accepting active RMA and it seems to have worked. I ran a port scanner and it does not show anything on 5056 which is what we have used for many many years. So I do not understand why the hang of hostmonitor caused this chain of events and now the default port no longer works ...
- Mon Jan 08, 2018 8:52 pm
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Crash Issue in 11.00 - Related to ActiveRMA
- Replies: 9
- Views: 24340
Alex I can reproduce the problem, I just change the Enabled=0 to Enabled=1 in the ActiveRMA section. Then I manually start Hostmonitor and I get the same values in the syslog. I though maybe we tried to start hostmonitor twice, but I am sure that is not the cause because I can easily duplicate the i...
- Mon Jan 08, 2018 8:40 pm
- Forum: Configuration, Maintenance, Troubleshooting
- Topic: Crash Issue in 11.00 - Related to ActiveRMA
- Replies: 9
- Views: 24340
Windows 2012 R2 Standard Xeon e5-2650 128 GB Ram. We have been running Hostmonitor on this Server for more than 2 years without any issues. RMA Manager does connect fine ( we have over 500 Active Agents) Running 6.00. We changed no settings at all before or after the crash, and the 500 agents have b...