Hi KS-Soft,

We are currently receiving the following error and cannot seem to keep the WMI Memory test method alive.

O/S: Windows Server 2008 R2 STD

Failure log error:
[9/25/2014 7:53 AM] 192.168.194.201 Windows socket error: An established connection was aborted by the software in your host machine (10053), on API 'send'

I have changed the port to "1056" on the remote monitoring agent, the service starts and test other methods successfully (CPU, DISK USAGE) Though only memory test on this server seems to provide problems.

Any ideas?
Back to top
View user's profile Send private message
KS-Soft Europe



Joined: 16 May 2006
Posts: 2832

PostPosted: Thu Sep 25, 2014 5:35 am    Post subject: Reply with quote

Could you please give us more information:
- Memory test (using WMI protocol) performed by Passive RMA agent and checks local (to RMA) system? Or may be RMA agent checks some other target system?
- Other test methos, performed by the same RMA agent work well?
- Do you have installed some antivirus monitors, personal firewall, content monitoring software on RMA(or target) system? Non standard winsock components?
Back to top
View user's profile Send private message Send e-mail Visit poster's website
KS-Soft



Joined: 03 Apr 2002
Posts: 12792
Location: USA

PostPosted: Thu Sep 25, 2014 5:40 am    Post subject: Reply with quote

Try to increase timeout.
What timeout specified at the moment?

Regards
Alex
Back to top
View user's profile Send private message Visit poster's website
bsahelpdesk



Joined: 22 Sep 2014
Posts: 11

PostPosted: Thu Sep 25, 2014 9:09 pm    Post subject: Reply with quote

Hi Alex

Memory test (using WMI protocol) performed by Passive RMA agent
all other tests are being performed well without issues (CPU, disk space)
No antivirus installed on client server.

timeout increases to 120 seconds
Back to top
View user's profile Send private message
KS-Soft



Joined: 03 Apr 2002
Posts: 12792
Location: USA

PostPosted: Fri Sep 26, 2014 8:32 am    Post subject: Reply with quote

Lets clarify:
1) This error mesaage recorded on system where agent is running, right?
----------
Failure log error:
[9/25/2014 7:53 AM] 192.168.194.201 Windows socket error: An established connection was aborted by the software in your host machine (10053), on API 'send'

----------
While HostMonitor shows Unknown test status and some error in Reply field? Probably "RMA: Cannot read" error?

2) Timeout 120 sec specified on RMA and HostMonitor side?

Can you perform any other WMI request using this agent?
Like Select HandleCount from Win32_Process where Caption='rma.exe'

Regards
Alex
Back to top
View user's profile Send private message Visit poster's website
bsahelpdesk



Joined: 22 Sep 2014
Posts: 11

PostPosted: Mon Sep 29, 2014 5:25 pm    Post subject: Reply with quote

1) The error is recorded on the remote agent on the server correct.
2) Timeout has been extended to 120 sec on both the agent and RMA manager, still no change
3) When I try perform any other WMI requests;

Select HandleCount from Win32_Process where Caption='RMA.EXE'

Error appears "Error: Access is denied"

What does this mean if the agent can connect to the server?

It seems utilising the WMI explorer the "Error: access is denied" always appears...

WMI service is started on the remote server also.

thanks
BSAHELPDESK
Back to top
View user's profile Send private message
KS-Soft



Joined: 03 Apr 2002
Posts: 12792
Location: USA

PostPosted: Tue Sep 30, 2014 4:05 am    Post subject: Reply with quote

Have you specified correct account for this test using Connection Manager?

Regards
Alex
Back to top
View user's profile Send private message Visit poster's website
bsahelpdesk



Joined: 22 Sep 2014
Posts: 11

PostPosted: Wed Oct 01, 2014 6:44 pm    Post subject: Reply with quote

All tests are running fine without any changes, I have checked the Connection Manager credentials and all ok!
Back to top
View user's profile Send private message
KS-Soft



Joined: 03 Apr 2002
Posts: 12792
Location: USA

PostPosted: Thu Oct 02, 2014 10:31 am    Post subject: Reply with quote

We have no idea what is wrong

HostMonitor version?
RMA version?
May we see test and Connection Manager settings? Please send to support@ks-soft.net

Regards
Alex
Back to top
View user's profile Send private message Visit poster's website
Display posts from previous:   
Post new topic   Reply to topic    KS-Soft Forum Index -> Configuration, Maintenance, Troubleshooting All times are GMT - 6 Hours
Page 1 of 1

 
Jump to:  
You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum


Powered by phpBB © 2001, 2005 phpBB Group

KS-Soft Forum Index